4
ADVANCED OPERATION
4-5
• The Lone Worker function
When no operation occurs for the ON Timer preset time.
L If a user pushes any key before the Reminder Timer
set time expires, the Emergency mode is canceled.
(Example)
• ON Timer: 60 minutes
• Reminder Timer: 60 seconds
60 min.
60 sec.
Operation
Time
ON Timer
Reminder
Timer
Emergency
Timer
Enters the
Emergency mode.
Sends an
Emergency call.
[PTT][PTT][PTT]
No operation
is detected.
With Stationary
z When no operation occurs for the ON Timer preset
time.
AND
z The transceiver is detected as stationary (no
motion) for the ON Timer set time.
L If a user pushes any key, or moves the transceiver
before the Reminder Timer set time expires, the
Emergency mode is canceled.
(Example)
• ON Timer: 60 minutes
• Reminder Timer: 60 seconds
60 min.
60 sec.
Stationary
Sensitivity
Operation Acceleration
Time
ON Timer
Reminder
Timer
Emergency
Timer
Enters the
Emergency mode.
Sends an
Emergency call.
[PTT][PTT][PTT]
No motion is
detected.
No operation
is detected.
Emergency call
D Transmitting an Emergency call (Continued)
The transceiver enters the Emergency mode through