37
13
SPECIFICATIONS
D Receiver
Receive system : Triple conversion
superheterodyne
Intermediate frequencies : 1st 266.7 MHz
2nd 19.65 MHz
3rd 450 kHz
Sensitivity (except spurious points; typical values):
FM 30117.995 MHz 0.32 µV
(at 12 dB SINAD) 118174.995 MHz 0.16 µV
175246.995 MHz 0.22µV
247329.995 MHz 0.4 µV
330379.995 MHz 0.32 µV
380469.995 MHz 0.18µV
470749.995 MHz 1.0 µV
750999.995 MHz 0.32 µV
10001199.995 MHz 0.79 µV
12001300 MHz 0.5 µV
WFM 76108.0 MHz 1.0 µV
(at 12 dB SINAD) 175221.995 MHz 1.0 µV
470770 MHz 5.6 µV
AM 118136.0 MHz 0.56 µV
(at 10 dB S/N) 222246.995 MHz 0.79 µV
247329.995 MHz 1.4 µV
Squelch sensitivity : 0.18 µV (144148 MHz)
0.22 µV (430450 MHz)
Selectivity :
FM, AM More than 15 kHz/6 dB
Less than 30 kHz/60 dB
WFM More than 150 kHz/6 dB
Image rejection ratio: More than 60 dB
(amateur bands only)
Audio output power : 100 mW typical at 10%
(at 3.0 V DC) distortion with an 8 load
All stated specifications are subject to change without
notice or obligation.

Table of Contents

Other manuals for Icom IC-Q7A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-Q7A and is the answer not in the manual?

Icom IC-Q7A Specifications

General IconGeneral
BrandIcom
ModelIC-Q7A
CategoryTransceiver
LanguageEnglish

Related product manuals