EasyManua.ls Logo

Icom IC-R8500 - Automatic Bank Limit;Skip Functions; Voice Scan Control Function

Icom IC-R8500
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
6
SCANS
Automatic bank limit/skip functions
When starting a scan, the following functions are
automatically turned ON by default; and the [SKIP]
and [BANK] switches are deactivated during scan.
The bank limit function
(for memory scan and select
memory scan)—The memory scan operates within
the selected bank only.
Turning OFF the automatic function
Push [MEMO] for 1 sec.
A display as at right appears.
Rotate the [M-CH] selector to
select the item, SKIP or
BANK.
Rotate the main dial to select
the function AUTO or MANU-
AL.
Push [MEMO] to return to the
previous display.
SKIP AUTO
SKIP MANUAL
BANK AUTO
BANK MANUAL
The skip function is turned ON automatical-
ly at scan start.
[SKIP] does not function during scan.
The bank limit function is turned ON au-
tomatically at scan start.
[BANK] does not function during scan.
The scan skip function is turned ON and
OFF by [SKIP] regardless of scan start.
The bank limit function is turned ON and
OFF by [BANK] regardless of scan start.
Voice scan control function
This function is useful when you don’t want unmodu-
lated signals pausing or cancelling a scan. When
activated, the receiver checks received signals for
voice components.
If a receiver signal includes voice components, and
the tone of the voice components changes within 1
sec., scan pauses (or stops). If the received signal
includes no voice components or the tone of the
voice components does not change within 1 sec.,
scan resumes.
To toggle the function ON and OFF, push [VSC].
“VSC” appears while it is activated.
The VSC function activates for any scan.
The VSC function resumes the scan on unmod-
ulated signals even when the resume condition is
set to “OFF” or “
”.
Scan edge 1
Scan
Skip
Scan pauses or is
cancelled.
Unmodulated
signal
Modulated
signal
Scan edge 2
FM VSC
OFF
kHz
DLY
ICOM- IC-R8500
VSC appears
The skip function
(for any scan except priority
scan)—memory channels specified as skip chan-
nels are not checked during memory scan and
select memory scan; the frequencies which are pro-
grammed into memory channels as skip channels
(not only in the skip bank but any memory chan-
nels) during programmed scan and auto memory
write scan.

Table of Contents

Other manuals for Icom IC-R8500

Related product manuals