@1 MEMORY SET SWITCH [M-SET] (p. 19)
Used to ‘copy and paste’ the displayed frequency
into another memory channel.
The first push is used to copy ( appears), and the sec-
ond push is used to paste ( disappears).
Frequency, mode, tuning step, memory name, etc. can
be programmed into a temporary memory.
@2
MEMORY CLEAR SWITCH [M-CL] (p. 19)
Push and hold to clear the contents of the displayed
memory.
Bank names cannot be cleared.
@3
MEMORY WRITE SWITCH [MW] (p. 19)
Push and hold to store the displayed frequency,
mode, tuning step, etc. into the selected memory
channel.
@4 BANK SWITCH [BANK] (p.17)
Push momentarily to toggle the bank limit func-
tion ON and OFF (p18).
While “BANK” appears, only memory channels within
the selected bank can be selected via the [M-CH] se-
lector.
Push for 1 sec. to increase/decrease the number of
memory channels in the selected bank (p. 21).
@5 MEMORY CHANNEL SELECTOR [M-CH] (p.18)
Selects a memory channel in normal use.
Clockwise rotation selects higher memory channel
numbers; counterclockwise rotation selects lower
memory channel numbers.
Selects a set mode item when quick set mode or
initial set mode is selected (p.30).
@6 DELAY/SPEED CONTROL [DELAY/SPEED] (p.28)
Adjusts the scan delay time or scan speed depend-
ing on the [DLY ] switch setting.
When scan delay time is assigned, this control adjusts
the scan delay time (scan pausing interval) during signal
reception. This setting is effective when “ ” is
selected for the scan resume condition.
When scan speed is assigned, this control adjusts the
scan speed. In this case, scan delay time is determined
while setting.
@7
SCAN SWITCHES [SCAN ]
All of these switches are related to the scan function
in some way as follows:
[MEMO] (p. 23)
Push momentarily to start/stop memory scan.
Push numeral keys, then this key to start memo-
ry scan in the specified bank.
Push this key, then a mode switch to activate
mode select scan function.
Push for 1 sec. to set automatic bank and skip
functions.
The bank limit function and/or memory skip functions
are activated automatically when “AUTO” is selected
and scan is started.
[SEL] (p. 23)
Push momentarily to start/stop memory select
scan.
Push for 1 sec. to set the memory channel as a
select
channel.
[PROG] (p. 24)
Push momentarily to start/stop programmed scan.
Push numeral keys, before or after pushing this
key to start programmed scan using the specified
scan edge group.
10 scan edge groups are available.
Push for 1 sec. to program scan edges for pro-
SCAN SET
D/S
M
3
1
PANEL DESCRIPTION
MODE
WFM
NB/AFC AGC 10dB 20dB
FM AM
APF
TS
TS
SPCH
SSB/CW
AF GAIN SQUELCH
PHONES
REC OUT
SLEEP/
REC
REMOTE
IF SHIFTAPC
SET
LOCK
COMMUNICATION RECEIVER
iC- r8500
POWER
SIGNAL
S
13579
+
20dB
+
60dB
FM
RECV
BANK
10-ATT-20
APF-NAGC-FAFCNB
SLEEP
LOCK
ICOM

Table of Contents

Other manuals for Icom IC-R8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-R8500 and is the answer not in the manual?

Icom IC-R8500 Specifications

General IconGeneral
Antenna Impedance50 Ω
Power Supply13.8 V DC ±15%
ModeAM, FM, WFM, CW
Channels1000
Tuning Steps10 kHz
Dynamic Range100 dB
IF Output10.7 MHz
Antenna InputSO-239

Related product manuals