DIGITAL REPEATER SETTING
13
3
Utility for ID-RP3 settings (Gateway settings)
Settings shown below are required if operating the repeater as a Gateway.
D Using a Gateway server
1. Select “Use Gateway Server” in “Gateway” (1)
L The option “Use Simple gateway” is usable only in Japan.
2. Enter the IP address of the port toward the repeater (2).
L Enter the IP address according to your environment.
3. Enter the UDP port number (3).
L Conrm the UDP port number is not a duplicate if using the Monitor function on the same IP address.
1
2
3
TIP: Using the Gateway function with multiple repeaters
Only one of the multiply-connected repeaters can be set
as a Gateway.
L “×” is displayed if multiple repeaters are set as a Gateway.
If the ID-RP1200VD in DD mode is included, set it as
a Gateway.
L “×” is displayed if other repeater is set as a Gateway