USING THE UTILITY FOR ID-RP3
3
1
Programming the repeater
D Programming through a USB cable
1. Connecting the PC and repeater
Connect the PC that the utility and the USB driver have been installed in and the repeater, as shown below.
L Turn OFF the repeater when connecting.
Connection example:
Type-B
ID-RP1200VD (Repeater ID: 3)
ID-RP4010V (Repeater ID: 2)
NOTE:
When using multiple repeaters, assign a different ID to each repeater, as shown above. This enables editing all
repeaters settings by connecting any one repeater to your PC.
To assign the ID, connect your PC to the [USB] port of the target repeater.
The edited setting data of each repeater can be saved as a single setting le (icf).
USB cable (Supplied with the repeater)
PC
TIP: Using the DD mode (For only the ID-RP1200VD)
Turn OFF the repeater once, set [DV/DD] select switch to [DD], and then restart the repeater.
The operating mode is not changeable while the repeater is ON, and not changeable by using the utility.