6
2
MENU
ATA (Automatic Tracking Aid)
ATA MENU
VECT
No.DISP OFF ALL
OWN VECT
ALARM
CPA LIMIT
TCPA LIMIT
TRUE
ON
ON
ON
OFF
REL
OFF
OFF
1.0NM
1 MIN
ATA
SEL
DATA
• OFF : Turn OFF the ATA function.
• ON : Turn ON the ATA function.
DNo.DISP
• OFF : Do not display any mark number.
• Sel : Display the selected mark number
only.
• ALL : Display all mark numbers.
DVECT
TRUE : Select the true vector mode.
• REL : Select the relative vector mode.
DOWN VECT
• OFF : Do not display your own ship’s vec-
tor.
• ON : Display your own ship’s vector.
DALARM (CPA/TCPA)
• OFF : Turn OFF the alarm function.
• ON : Turn ON the alarm function.
DCPA* LIMIT
• 0.1 to 10.0NM : Set the CPA (Closest Point of Ap-
proach) limit with [t] [u].
DTCPA* LIMIT
• 1 to 60MIN : Set the TCPA (Time to CPA) limit time
with [t] [u].
* CPA/TCPA: Closest Point of Approach and Time to Closest
Point of Approach limit is defined by the observer to given
warning when a target or targets are close to within those
limits from your own ship.
INT. SETTING
INT. SETTING
BRG INPUT
SPD INPUT
TX INH START
TX INH ANGLE
SAVE TIME
SYMBOL
CHARACTER BRILL
NMEA
30M
LOG
6M 15M
MANUAL
AUTO
N+1 AUX GPS
GPS
0
˚
0
˚
KEY ILLUM
MAG VAR
1 23
1 2 3
123 4
7.2
˚
W
1M
DMAG VAR
• AUTO : Automatically revise magnetic variations.
NOTE: NMEA data is required. NEVER select
“AUTO” without NMEA data; incorrect varia-
tion data may entered. (p. 38)
• MANUAL : Revise magnetic variation manually.
Push [u] to select [MANUAL], then push [q].
Set the revised value with [t] [u]. Push [q]
or [MENU] to exit the menu.
DBRG INPUT
• NMEA : NMEA0183 bearing data format.
• N+1 : N+1 data format.
• AUX : Other format.
• GPS : Reads NMEA0183 COG format data as
HDG format.
DSPD INPUT
• GPS : Use the GPS NMEA speed data.
• LOG : Use the speed sensor data.
DTX INH START
• 0 to 359° : Push [t] [u] to enter the start point of
the TX inhibit area.
DTX INH ANGLE
• 0 to 90° : Push [t] [u] to enter the TX inhibit area.
DSAVE TIME
• 1M, 6M, 15M or 30M
: Select the standby time during the save
mode.
The radar for TX interval scan is xed at 10
revolutions.
DSYMBOL
• 1/2/3 : Select the symbol brightness.
DCHARACTER
• 1/2/3 : Select the character brightness.
DKEY ILLUM
• 1/2/3/4 : Select the key illumination brightness.