37
13
SPECIFICATIONS
D Scanner unit
◆ EX-2714 (Radome)
• Type : 2 feet Slotted Waveguide Array, enclosed in a radome.
• Rotation speed (typical) : 24 rpm, 36 rpm, 48 rpm*
*only [CHN], [CHN-01], [EXP], [EXP-01]
• Beam width (typical) : Horizontal beam 4˚
Vertical beam 22˚
• Side lobe (typical) :
[CHN], [CHN-01], [EXP], [EXP-01] –18 dB
[CHN-02], [EXP-02] –22 dB
• Polarization : Horizontal
• Transmission frequency : 9410 MHz ±30 MHz P0N
• Peak output power : 4 kW
• Pulse width :
[CHN], [CHN-01], [EXP], [EXP-01] 80 ns/2880 Hz, 80 ns/2160 Hz, 250 ns/2160 Hz,
350 ns/2160 Hz, 900 ns/720 Hz
[CHN-02], [EXP-02] 80 ns/2160 Hz, 80 ns/1440 Hz, 250 ns/1440 Hz,
350 ns/1440 Hz, 350 ns/720 Hz, 900 ns/720 Hz
• Mixer and Local Oscillator : Microwave Integrated Circuit
• Transmitting Tube : Magnetron MAF1421B
• Modulator : FET switching
• Duplexer : Circulator
• Tuning system : Automatic/manual selectable
• Intermediate frequency : 60 MHz
• IF Band width : 10 MHz, 3 MHz
• Dimensions :
[CHN], [CHN-01], [EXP], [EXP-01] 607 (Ø)×243 (H) mm; 23.9 (Ø)×9.6 (H) in
[CHN-02], [EXP-02]
640 (W)
×256 (H)×640 (D) mm,
25.2 (W)×10.1 (H)×25.2 (D) in
• Usable temperature range : –25˚C to +70˚C; –13˚F to 158˚F
• Relative Humidity : Less than 95% at 40˚C (+104˚F)
• Weight : Approximately 8 kg; 17.6 lb (without cable)
◆ EX-2780 (Open array)
• Type : 120 cm Slotted Waveguide Array
• Rotation speed (typical) : 22 rpm
(only MR-1000TIII), 24 rpm, 36 rpm, 48 rpm
• Beam width (typical) : Horizontal beam 2˚
Vertical beam 25˚
• Side lobe (typical) : –24 dB
• Polarization : Horizontal
• Transmission frequency : 9410 MHz ±30 MHz P0N
• Peak output power : 4 kW (MR-1000TII), 6 kW (MR-1000TIII)
• Pulse width : 80 ns/2880Hz, 80 ns/2160 Hz, 250 ns/2160 Hz,
350 ns/2160 Hz, 900 ns/720 Hz, 900 ns/660 Hz*
*only MR-1000TIII
• Mixer and Local Oscillator : Microwave Integrated Circuit
• Transmitting Tube : Magnetron MAF1421B (MR-1000TII)
MAF1422B (MR-1000TIII)
• Modulator : FET switching
• Duplexer : Circulator
• Tuning system : Automatic/manual selectable
• Intermediate frequency : 60 MHz
• IF Band width : 10 MHz, 3 MHz
• Diameter of rotation/height : 1205/381 mm; 47.4/15 in
• Usable temperature range : –25˚C to +70˚C; –13˚F to 158˚F
• Relative Humidity : Less than 95% at 40˚C (+104˚F)
• Weight : Approximately 17 kg; 37.5 lb (without cable)
All stated specifications are subject to change without notice or obligation.