EasyManua.ls Logo

Icom MR-1000RII - ATA Target Tracking

Icom MR-1000RII
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
DISTANCE AND DIRECTION MEASUREMENTS
13
Distance measurement
Two measurement procedures can be used with this
radar. Use them separately or jointly is possible.
The distance unit, nautical miles (NM) or kilometers
(KM) is selected in the FUNCTION menu (p. 5).
DUsing the fixed rings
1
(0.25)
T.VECT
0.900NM
NM
CURS
SOG 0.0KT
H UP
014.T
HDG
IR
ES
EBL1
EBL2
W
PT
VRM1
VRM2
CURS 34˚ 37.72N
13 34.42E
Fixed ring
Ring range readout
q Push [MENU]/[ ] one or more times to call up the
FUNCTION menu.
w Hold down [q] until the “RING” section becomes
highlighted.
e Push [u] to select RING function ON and display
the fixed ring.
The interval range appears on the right of the screen
range readout.
The ring range is xed depending on the screen range.
(See below.)
r Push [MENU]/[ ] one or more times to exit the
menu.
t To clear the fixed rings, push [t] to select OFF in
step e above.
Range (nm)
Ring (nm)
1 1.5 234681216243236 48*
1
8
1
4
1
2
3
4
255346 46464646466
1122 44886
64
72
46
1216
1
20
1
20
1
10
1
4
1
4
1
4
1
2
1
2
NOTE: When the screen is shifted, the number of rings may differ.
*Available for the MR-1000TII/TIII.
Available for the MR-1000TIII only.
DUsing the variable range marker
q
Push [EBL1 (VRM1)]/[ ] to display VRM1
and EBL1; then push [p] or [q] to set the marker.
The range between the ship and the target is indicated
in the VRM readouts.
w
Push [EBL2 (VRM2)]/[ ] to display VRM2
and EBL2; then push [p] or [q] to set the marker.
The range between the ship and the target is indicated
in VRM readouts.
When VRM1 and EBL1 are displayed, the center of
VRM2 appears at the intersection point of VRM1 and
EBL1.
The VRM2 disappears when [EBL1 (VRM1)] is pushed.
e Push [EBL1 (VRM1)]/[ ] to exit the
menu display.
TYPE
RING
VRM1
VRM2
DESCRIPTION
Displays fixed rings.
Suitable for rough estimations from your
own ship to any target.
Displays a variable range marker and
activated by [p ] [q ] for the range
marker selector.
Suitable for accurate measurements
from your own ship to a target.
Normally functions the same as VRM1.
When the VRM1 and EBL1 selects a
target, the center of VRM2 appears at
the intersection point.
Suitable for accurate measurements
from target to target.

Table of Contents

Other manuals for Icom MR-1000RII

Related product manuals