10
31
SERVICE MAN MENU
Service man menu
CAUTION: The SERVICE MAN MENU is available
for service purposes only. DO NOT change any
setting on the menu, otherwise the equipment may
not operate at it’s original performance.
To open the “SERVICE MAN” menu.
Push [MENU]/[
] one or more times to show the
“SERVICE MAN” menu.
Select the language
Menu screens can be displayed in ENGLISH and
(CHINESE).*
* Depending on version, menu screen can be displayed in
English and Korean.
After opening the “SERVICE MAN” menu;
q Push [p] to show the present language.
w Push [t] [u] to select the desired language, then
push [q] to continue the setting.
e Push [MENU]/[ ] to exit the “SERVICE MAN”
menu.
SERVICE MAN
SPD ADJ.
HDG ADJ. 0.0
˚
HV
SETUP MEMORY RECALL
RANGE
24000 MONITOR
HEATER
5731.0H
TX TIME
30.0
OUTPUT
ENGLISH
VOLTAGE
SAVE MG
340
75
3.0
0.55
TIMING ADJ.
1/8 3/4 2 6
1/4 1 3 8
1/2 1.5 4 12
16
24
32
36 72
48
64
DTIMING ADJ.
• Corrects the distance.
DHDG ADJ.
• Adjusts the electronic heading line adjustment.
DSPD ADJ.
• Enter the pulse rate of the speed sensor.
DRANGE
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36,
48*, 64
, 72
: Choose the selectable screen range.
*MR-1000TII/TIII
MR-1000TIII only
D SETUP MEMORY
The present value is displayed by pushing [u], then
select the desired item from “RECALL and “SAVE”
using [q].
q Push [u] to display “RECALL” and “SAVE”.
w Push [p] [q] to select “RECALL or “SAVE”.
e Push [u].
“SURE ?” is displayed.
r Push [u] to perform.
t Push [u]
to cancel
.
When recall is performed without saving a setup,
it will become an initial value at the time of factory
shipments.
DOther readouts
• OUTPUT VOLTAGE
: Shows the voltage level for the
scanner unit from the display
unit.
• HV (High voltage) : Shows the voltage level in the
high-voltage unit in the scanner
unit.
• MONITOR : Shows the voltage level for check-
ing the receiver unit operation.
• HEATER : Shows the heater current.
• MG : Shows the current level for the
Magnetron.
TX TIME : Shows the total transmitted time.