Error message list
*
1
Push any key to cancel the error message and beep tone. Turn OFF the power, then check the external data
cable connection.
*
2
An electricity failure may occur, turn OFF the power, then consult your dealer or service person.
*
3
Push any key to cancel the error message and beep tone.
*
4
Turn OFF the power, then check the system cable connections.
11
34
ERROR MESSAGE
Message Condition
BRG INPUT FAIL*
1
The Azimuth signal is interrupted. An alarm sounds within 5 seconds and
the display reverts to H UP mode in approximately 1 minute.
TRIG SIGNAL FAIL*
1
If the TRIGGER signal is interrupted for more than 15 seconds, an
alarm sounds.
SHM SIGNAL FAIL*
2
If the SHM signal is interrupted for more than 15 seconds, an alarm
sounds.
POSN INPUT FAIL*
1
If the position signal is interrupted for more than 15 seconds, an
alarm sounds.
CHECK SCANNER CONNECTION*
4
The system cable may not be connected properly.