MVS6000
4-2
MVS6000 System Level Manual/1.0/Dec-2001
4.1 Memory Storage
Data fields are not used anymore on the MVS600x board. The images are not stored at a
predefined location, but in a dynamically allocated memory. This way, no space is lost.
The images are identified by means of their “tag”. The algorithms use these tags instead of the
data field number to specify the image to be processed or shown.
4.2 Timing Kits
On the MVS600x board, there is only one timing kit per camera/mode. The integration time is set
by software and linked to the illumination time. This is different compared to the MVS3x0 board.
4.3 Camera Selection
The CNF_edit program (see pages 3-21 and 3-25) is the only place where you can specify the
camera configuration (type and mode) in the ICOS software. This means that there can be no
incompatible settings.
Note: ADIMEC cameras also has to be configured with their own m12pc32 program.