FIRE OR EXPLOSION HAZARD
Failure to properly install metal gas connector
could result in death, personal injury and/or
property damage.
A flexible corrugated metal gas connector must be
properly installed, shall not extend through the side
of the furnace,and shall not be used inside the
furnace.
Black iron pipe shall be installed at the furnace gas
control valve and extend a minimum of 2" outside
furnace casing.
6.
7.
Use black iron or steel pipe and fittings or other pipe ap-
proved by local code.
Use ground joint unions and install a drip leg no less than 3"
long to trap dirt and moisture before it can enter gas valve.
Use two pipe wrenches when making connections to pre-
vent gas valve from turning•
Install a manual shut-off valve external to furnace casing
and tighten all joints securely•
If local codes allow the use of flexible gas appliance connec-
tors, always use a new, listed connector• Do not use a con-
nector which has previously serviced another gas
appliance•
iiiiiiii_i!!i!i!i!i!i!::_i;:;:;:il;i:::::i¸_i_!_i_i!_iii_i_ii_i!i!i!iiii_iii!iiiiiiiiiiiii_ii_iii!!_iiiiiiiiiiiiiiiiii_iiiii_iiiiiiiiiiiiiiiiiiiiiiii_i;i_i!i;i_ii_ii_ii_ii_ii_ii_ii_
Typical Gas Pipingfor Upflow
Drip Leg and Union, Union* should be outside the GasPipe Grommet (Single Pipe)
cabinet•Manualshut-off valveMUST be upstreamof vM_;eUa,shut-off /
dripleg, union, and furnace. _ "--......_ _,_ _ __
Use elbows and 3" pipenipple to connectvalveto _ _ _._ _._
pipingwhenusing rightside gas pipeentry,_ _ _ _, _ _ _
'n_P_,Pe _ _ _ .._ hMOdee_
4 :L, s.,c
bUcn_o nem:fYcf:a irn Stcaellse.dinside the ca binet when n ecessa ry _ "_d _
Alterative
installation
may
or2
re
8S
25-24-86
iiiiiiiiiiiiiiiiiiii !i!ii i ! i i i i i i i i i i i i i i i i iiii:iiT pica,GasPipingforDownf,ow
Use elbows and 3" pipe nipple to connect valve
to piping when using left side gas pipe entry.
LPLow pressure
switchREQUIRED.
Manualshut-
valve
Drip Leg and Union, Union* should
the cabinet. Manual shut-off valve MUST be
upstream of dripleg, union, and furnace.
_Union may be installed inside the cabinet when necessary
because of clearances.
Gas Pipe Grommet
(Single Pipe)
44001 102102
25-25-46a