53
FaULT FINDINg
FaULT FINDINg F aULT FINDINg F aULT FINDINg F aULT FINDINg F aULT FINDINg
Ideal Logic Code Combi ES - Installation and Servicing
75
aLTERNa TINg ‘L aND ‘6’ - FaLsE FLaME LOCKOUT
Reset the boiler, does Boiler Work OK?
NO
Check routing and integrity of internal boiler




pins connected to the electrode?

Replace Flame Detection Electrode

NO

76
aLTERNa TINg ‘F’ aND ‘1’ - LOW Wa TER pREssURE

all isolation and radiator valves open (check pressure

NO
Fill and vent the system and open all isolation valves

Are connections on water pressure sensor secure?
REsET pROCEDURE
NO

Replace water pressure sensor


Other manuals for IDEAL Logic Code Combi ES26

Related product manuals