6: D
EVICES
6-14 FC6A S
ERIES
MICROS
MART
U
SER
S
M
ANUAL
FC9Y-B1722
M8340 = User communication receive instruction being executed on client connection 13
M8341 = User communication receive instruction being executed on client connection 14
M8342 = User communication receive instruction being executed on client connection 15
M8343 = User communication receive instruction being executed on client connection 16
M8211: HMI Module Send E-mail Server Settings Initialization
When M8211 is turned on, the settings for the send E-mail server on the HMI-Ethernet port are initialized.
M8212 to M8221, M8345 to M8354: Connection Status
While connected to a network device via the maintenance communication server, user communication server/client, or Modbus TCP
server/client, the connection status is turned on. While not connected to a network device, the connection status is turned off.
M8212 = Connection 1
M8213 = Connection 2
M8214 = Connection 3
M8215 = Connection 4
M8216 = Connection 5
M8217 = Connection 6
M8220 = Connection 7
M8221 = Connection 8
M8345 = Connection 9
M8346 = Connection 10
M8347 = Connection 11
M8350 = Connection 12
M8351 = Connection 13
M8352 = Connection 14
M8353 = Connection 15
M8354 = Connection 16
M8222 to M8231, M8355 to M8364: Disconnect User Communication Connection
When connected to a remote host via user communication, the corresponding connection is disconnected when M8222 to
M8231 is turned on.
M8222 = Connection 1
M8223 = Connection 2
M8224 = Connection 3
M8225 = Connection 4
M8226 = Connection 5
M8227 = Connection 6
M8230 = Connection 7
M8231 = Connection 8
M8355 = Connection 9
M8356 = Connection 10
M8357 = Connection 11
M8360 = Connection 12
M8361 = Connection 13
M8362 = Connection 14
M8363 = Connection 15
M8364 = Connection 16
These relays are enabled only when a user communication client is used.
M8232: HMI Module Connection Information Reference Connection Status
M8232 is turned on when there is a connection with the connection number specified by D8429. M8232 is turned off when there
is no connection.
M8250: Download from SD Memory Card Execution Flag
When M8250 is turned on, a ZLD file is downloaded from the SD memory card. The file that will be downloaded is the ZLD file
specified in the autoexec.ini file.
M8251: Upload to SD Memory Card Execution Flag
When M8251 is turned on, a ZLD file is uploaded to the SD memory card.
A ZLD file is created with the file name specified in the autoexec.ini file.

Table of Contents

Other manuals for IDEC MICROSmart FC6A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICROSmart FC6A Series and is the answer not in the manual?

IDEC MICROSmart FC6A Series Specifications

General IconGeneral
BrandIDEC
ModelMICROSmart FC6A Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals