Operation
173
Bad Accuracy – Without a Laser Catch (cont.)
• Redo the bucket calibration.
• If only the tilt accuracy is bad:
• Redo the tilt bucket calibration. You’ll first need to delete the existing tilt calibration through the machine parameters by un-checking the appropriate box.
• If the tilt accuracy is still bad, follow one more time very accurately the instructions in the “Tilt How-to” document and do it again. The assignments and
orthogonal orientations of Tilt A & B to each other is crucial.
Bad Accuracy – After Laser Catch Only
• Check the rotating laser’s accuracy & calibration.
• Make sure that there’s no reflection of the laser beam.
• Re-measure the AB & AC laser receiver calibration measurements and compare with the values entered in the machine parameter section.
If the values are off more that ± .4” (1cm) you should change the values manually or re-calibrate the laser receiver using the automatic
laser receiver calibration.
• Try an on-grade (“fine”) laser catch. If there is a difference to the catch results with the “medium” setting, the Combo Sensor needs to be
changed.
Cbox Doesn’t Boot – LED Display is Working
• Is the Control Box connected to the cradle holder correctly, not accidently put in upside down?
• Are the connectors that snap the Control Box into place in good condition?