Checking the System Accuracy
Machine & Bucket Calibration Check for Reach
Make sure that the surface on the ground is fairly level from front to back.
Place the bucket on a solid spot far away from the front of the machine with the bucket fully open.
Lock the center tooth on the main working screen by taping on the center tooth on the bucket symbol on the left hand side of the screen.
Mark the spot on the ground where the buckets center is placed.
Enable the Reach function.
Confirm the axis alignment.
Set “0” as the reach on the Control Box.
Move the bucket as close to the cab as possible. Do NOT rotate the cab!
Close the bucket to an approximate floating position.
Place the bucket tip/edge on the ground with the center tooth/blade touching the ground.
Measure from the reference spot up to the center of the bucket tip/blade.
Compare the measurement with the reading on the screen.
Being 1/3 inch (1 cm) off is fine.