EasyManuals Logo

IEI Technology MiniMax 3 User Manual

Default Icon
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Section 1: System Features and Specifications IEI MiniMax 3 Installation/Programming Manual
1.2 Specifications
The following table lists the Electrical, mechanical and environmental specifications.
Table 2: Specifications
Electrical
Power Supply
16.5VAC 40VA or 50VA Class 2 Transformer (Revere # RT-G1640SL/M, Revere #
RT-G1650SL/M or Globtek, Inc. # DA-40-16.5G)
Current Requirements 110mA (backplane with module)
Front End 13.8 VDC, 300 mA (max. current draw)
Lock Output 13.8VDC or 16.5VAC, 600mA (max. current draw)
Aux 13.8VDC, 100mA (max. current draw)
Main Relay 12-24 VAC/DC, 2A (max. contact current)
Alarm Shunt, Door Ajar
and Forced Door Relays
12-24VAC/DC, 1A (max. contact current)
REX/Door Loop Dry contact closure
Wiring Requirements
RS-485 Cable 24AWG, shielded, two twisted-pair telephone cable with a shunt capacitance of 16
pF/Ft (required only when using software)
Front End Cable Stranded wire with overall foil shield.
REX/Door Loop Cable Stranded wire with overall foil shield.
Mechanical
Enclosure Surface mount
Height 3.56” (9.04cm)
Width 11.29” (28.67 cm)
Length 11.31” (28.7 cm)
Material 19 gauge steel
Environmental
Temperature Tolerance
-20°F to 130°F (-28°C to 54°C)
Recommended Use For indoor use only
1.3 System Defaults
The following table lists the default settings for the Max 3 Door Control Module.
Table 3: System Defaults
Option Default Setting Option Default Setting
Master Code 1234 Main Relay Time 5 Seconds
Door Ajar Output Time 30 Seconds Forced Door Output Time 10 Seconds
Audio Keypress Feedback Enabled Visual Keypress Feedback Enabled
User Lockout Enabled User Lockout Type By Location
Time Zones Disabled Auto-Unlock Disabled
First-In Auto-Unlock Disabled User Timezone 24 Hours
Daylight Savings Time Enabled DST Format US
Wiegand LED State Active Low Wiegand Sounder State Active Low
Error Lockout Threshold 3 Attempts Error Lockout Duration 10 Seconds
Extended Unlock Time 10 Seconds Facility Code 11
Door Number 1
Auto-Unlock Time Zone
(Without software)
9 A.M to 5 P.M.; Monday
through Friday
Page 6 of 48 Document #: 6055672, Rev 1.0 D1c