EasyManua.ls Logo

IFM Electronic O1D155 - 9 Operating Modes; 9.1 Run Mode; 9.2 Display Mode; 9.3 Object Reflectivity

IFM Electronic O1D155
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
UK
9 Operating modes
9.1 Run mode
The run mode is the normal operating mode�
After power on the unit is in the Run mode� It carries out its monitoring function
and generates output signals according to the set parameters�
The display indicates the current distance, the yellow LEDs signal the switching
status of the outputs�
9.2 Display mode
Indication of the parameters and the set parameter values�
Press [MODE/ENTER] briefly
> Unit goes to the Display mode� Internally it remains in the operating mode�
The set parameter values can be read�
To scroll through the parameters, press [MODE/ENTER] briefly
To display the respective parameter value, press [SET] briefly
> After 15 s the unit returns to the Run mode�
9.3 Object reflectivity
Display of the object reflectivity (formerly: align mode)�
Press [SET] in the Run mode�
> The unit displays an orientation value for the object reflectivity
(e�g� +100 corresponds to a white object, +020 corresponds to a grey object)�
9.4 Programming mode
Setting the parameter values → 10.1 Parameter setting in general

Table of Contents