10 Parameter setting
During parameter setting the unit remains internally in the operating mode� It
continues its monitoring function with the existing parameters until the change has
been finished�
10.1 Parameter setting in general
10.1.1 Setting of the parameter value
Select the display unit [Uni] before you define the values for the
parameters� In case of subsequent changes of the display unit rounding
errors during internal conversion to other units may falsify the set values�
→ 10.2.1 Selection of the display unit
1
Selection of the parameter
Press [MODE/ENTER] until the
requested parameter is displayed�



2
Setting of the parameter value
Press [SET] and keep it pressed�
> The current parameter value flashes
for 5 s�
Increase the setting value
incrementally by pressing the button
once or
continuously
by pressing it
permanently



Decrease the value: let the display move to the maximum setting value� Then the
cycle starts again at the minimum setting value�
3
Confirmation of the parameter
value
Press [MODE/ENTER] briefly
> The parameter is displayed again; the
new parameter value is effective�



4
Setting of other parameters
Start again with step 1�
5
Finishing the parameter setting
Wait for 15 s or press [MODE/ENTER]�
> The current measured value is displayed�