EasyManuals Logo

Ihse 474 Series User Manual

Default Icon
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
Draco KVM Extender
52 2014-04-15
Compression
Parameter Function
MEDCPRATE Activate medium compression rate
MINCPRATE Activate low compression rate
MAXCPRATE Activate high compression rate
Parallel Operation
Parameter Function
KBDCON
Activate Keyboard Connect (only with redundant
CPU Units)
MOUCON
Activate Mouse Connect (only with redundant
CPU Units)
RELEASETIME=n
Release timer n = 0...9 seconds for Mouse and
Keyboard Connect, without parameter =
10 seconds
5.5.2 Parameters for CON Units
You can write the following parameters into the configuration file of a CON
Unit.
Output Settings
Parameter Function
1080p50Hz Always display 50 Hz when using 1920x1080
DISEXTOSD Deactivate extender OSD
ENAFRAME
Show orange colored frame when losing
extender connection
ENAHOLDPIC
Show last transmitted picture highlighted by an
orange colored frame when losing connection
ENADDCTX
Activate DDC transmission by unplugging and
connecting the monitor back to the CON Unit
CENTERMODE
Simulate the native resolution of Dual-Link
monitors by an additional black frame in order to
enable Instant Switching (482 series only).