EasyManuals Logo

IMC C SERIES User Manual

IMC C SERIES
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
© 2018 imc Test & Measurement GmbH
imc C-SERIES - Manual, Version 4 R 3 - 2018-10-19
115CS-7008-FD, CL-7016-FD
Possible initial unbalance
input range [mV/V]
bridge balancing
(VB = 2.5 V) [mV/V]
bridge balancing
(VB = 5 V) [mV/V
bridge balancing
(VB = 10 V) [mV/V
±1000
200
500
240
±500
500
100
700
±200
40
400
60
±100
140
20
200
±50
200
70
10
±20
20
100
35
±10
30
14
50
±5
7
18
7
±2
9
3,5
10
±1
-
4,5
2
±0,5
-
-
5

Table of Contents