17
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
1.10 REMOTE CONTROLS AND ROOM
CHRONOTHERMOSTATS OPTIONAL
e boiler is prepared for the application of room chrono-thermo-
stats or remote controls, which are available as optional kits
(Fig. 9).
All Immergas chrono-thermostats are connected with 2 wires
only.
Carefully read the user and assembly instructions contained in
the accessory kit.
Disconnect power to the unit before
making any electrical connections.
9
On/O Immergas digital chrono-thermostat.
e chrono-thermostat allows:
- set two room temperature value: one for day (comfort tempera-
ture) and one for night (reduced temperature);
- set a weekly programme with four daily switch on and switch o
times;
- selecting the required function mode from the various possible
alternatives:
manual mode (with adjustable temperature);
automatic mode (with set programme);
forced automatic operation (momentarily changing the tem-
perature of the automatic program).
e chrono-thermostat is powered by two 1.5V LR 6 type alkaline
batteries.
“Comando Amico Remoto” (Remote Control Device)
V2
(CAR
V2
) with climate chrono-thermostat function.
In addition to the functions described in the previous point, the
CAR
V2
panel enables the user to control all the important infor-
mation regarding operation of the appliance and the heating sys-
tem with the opportunity to easily intervene on the previously set
parameters, without having to go to where the appliance is in-
stalled.
e panel is provided with self-diagnosis to display any boiler
functioning anomalies.
e climate chrono-thermostat incorporated into the remote
panel enables the system ow temperature to be adjusted to the
actual needs of the room being heated, in order to obtain the de-
sired room temperature with extreme precision and therefore
with evident saving in running costs.
e CAR
V2
is fed directly by the boiler by means of the same 2
wires used for the transmission of data between the boiler and de-
vice.
“Comando Amico Remoto” (Remote Control Device)
V2
or On/
O chrono-thermostat electrical connection (Optional).
e operations described below must be
performed aer having removed the
voltage from the appliance.
Any On/O room thermostat or chrono-thermostat must be con-
nected to terminals 44/40 and 41, eliminating jumper X40.
Make sure that the On/O thermostat contact is of the “clean”
type, i.e. independent of the mains voltage, otherwise the P.C.B.
would be damaged.
Any Comando Amico Remoto (remote control) V2 must be con-
nected to terminals 44/40 and 41, eliminating jumper X40 on the
P.C.B. (Fig. 40).
e boiler can only be connected to one remote control.
If the Comando Amico Remoto remote control
V2
or any
other On/O chrono-thermostat is used arrange two
separate lines in compliance with current regulations
regarding electrical systems.
Ensure elimination of this risk before making the boiler
electrical connections.