iNetVu Troubleshooting Guide - 1201 Flyaway
2. If the Mobile Platform physically moves but the angle doesn’t change
Possible Causes:
• 7000 Controller
• 15 Amp Fuse
• Flyaway Control Cable
• Internal Wiring
• Azimuth Potentiometer
a. Please ensure the Flyaway Control Cable is securely connected to the 7000 Controller and
Platform. Reseat this cable at both ends and try again.
b. If you are still experiencing issues please use the Sensor Circuit Diagram on the following page to
confirm continuity of the Control Cable. Set the voltmeter to beeper or continuity mode. If the
Control Cable passes continuity, this will conclude the issue is the Azimuth Encoder or Internal
Wiring. Please contact C-COM Technical Support for further assistance.
Sensor Continuity Test