10 STANDARDS
10.1 ELECTRICAL CONSUMPTIONS
• Max power supply :
o iUI120 < 24W
Value measured for Power supply 12V at 25°C
• Average Power device waiting for host solicitation :
o iUI120 < 1,44W
Value measured for Power supply 12V at 25°C
• Max Power device in stand-by mode :
o iUI120 < 4,8 mW
Value measured for Power supply 12V at 25°C
• Back up battery life
o 1 storage year + 7 years in field at 45 days/year storage rate (25°C)
10.2 TEMPERATURE AND HUMIDITY
• Operating & Storage conditions :
o Relative humidity: 5% to 85% non-condensing.
o External temperature range: -20 °C to 65 °C.
10.3 ENVIRONMENTAL SPECIFICATION CONTINUED
• Operating conditions :
o Vibrations resistance:
NF EN 60068-2-6 and the below conditions ( 10 tests sequences
per axis ) :
• From 5Hz to 9Hz with 3,3mm amplitude
• From 9Hz to 200Hz with 10m/s² acceleration
• From 200Hz to 500Hz with 15m/s² acceleration
• Endurance 30 mn on each resonance frequency
o Bumps resistance:
NF EN 60068-2-29. E
• Each direction, 500 drops 1/2 sinus 25g - 6ms
• Degradation iUI120 specification:
o Certified anti-tamper and attack resistant.