3.11 Antenna stand (AS)
3.11.1 General
Supported devices
◦ Antenna stand (AS): 0x60..
The X-Axis is used here for polarisation!
Can only change polarisation
3.11.2 Register
Addressing
Command Return Value Description
LD d DV d Load X-Axis, numerical addressing
Valid values for d: 0, 4, 8, 12
LD ASd DV Index of ASd from
*OPT? return
Load X-axis (here for polarisation)
Valid values for d: 1, 2, 3, ...
Read Commands
Command Return Value Description
BU 0 or 1
Motor Operational Status of current axis
0: Motor is off
1: Motor is on
P? 0 or 1
Polarisation, 0: horizontal, 1: vertical
Control Commands
Command Return Value Description
ST 1 Stops all movements in all connected devices
PV 1 Polarises vertically
PH 1 Polarises horizontally
© innco systems GmbH Schwarzenfeld/Germany
Erlenweg 12, 92521 Schwarzenfeld/Germany Phone: +49 9435 301659 0 Fax: +49 9435 301659 99