10
Version 2.02 December-2002
3.8 EMERGENCY ALARM ACTIVATION. -PANIC, FIRE AND MEDICAL ALARMS.
Enter the Isolate mode. (NEXT 21 for Zone Inputs OR NEXT 22 for System Inputs)
Enter PIN; ... , then , , OR , ,
The <ARM> and <HOME> Lamps will flash together.
The Zone Lamps will indicate the Inputs that are Isolated.
Isolate / De-Isolate Zone Inputs or System Inputs.
Enter the Zone Input or System Input number; ... (One or Two digits), then .
To Isolate or De-Isolate more Inputs, simply repeat this step for each Input.
System Input numbers are listed in the “TABLES” section at the rear of this manual.
An Isolated Zone Input is De-Isolated by following the same procedure.
When the Input is De-isolated, the Zone Lamp will be turned Off.
Exit the Isolate Zone mode.
Press
While any Zone Input is Isolated, the relevant <Zone Lamp> will flash slowly.
While any System Input is Isolated the <FAULT> Lamp will flash slowly.
3.7 ISOLATING (BYPASSING): ZONE INPUTS NEXT 21
SYSTEM INPUTS NEXT 22
Depending on the configuration of the Emergency Alarm options, each different Emergency alarm
can activate the Siren and/or the Dialer communications.
Consult with the Installer to detemine how each Emergency Alarm will operate.
The Emergency Alarms are activated by pressing two specific keys on the Terminal keypad
simultaneously.
PANIC and keys pressed at the same time.
FIRE and keys pressed at the same time.
MEDICAL and keys pressed at the same time.
Emergency Alarms are cleared by Entering PIN; ... , then .
or by Disarming the system.