12
Version 2.02 December-2002
1. Enter the View Alarm History Mode.
Press , , .
Any Zone Inputs that had an alarm during the last Armed period will be displayed on the Zone
Lamps. Press to exit.
3.12 VIEW ALARM HISTORY. NEXT 12
1. Enter the View Fault History Mode.
If the <FAULT> Lamp is On, or has been On, and you wish to view the cause of the Fault:
Press , , .
Any System Inputs that have had an alarm during the last five Armed periods will be displayed on
the Zone Lamps in the following manner: Zone Lamp Flashing: System Input currently in alarm.
Zone Lamp ON: System Input has had an alarm.
Press to exit.
3.13 VIEW FAULT HISTORY. NEXT 13
LAMP EXPLANATION / ACTION
1 AC Fail. AC Mains power to the system has been interrupted and the system is
operating on backup battery power. Check that the AC supply for the system
is present and is turned on. If you cannot rectify the problem, call for service.
2 Low battery. Battery voltage is too low to provide backup power if AC fails.
Call for service.
3 Cabinet Tamper. Interference with the equipment cabinet. Call for service.
4 Siren monitor. Siren speaker is disconnected. Call for service.
5 PWR fuse. Power fuse is blown. Call for service.
6 Battery fuse. Backup Battery fuse is blown. Call for service.
7 Comms fail. System has failed to report. Call for service.
8 System reset. All power to the system has been interrupted.
Enter: PIN Code, <OFF> on the Terminal keypad to Clear.
You should reset the Time and Date. (NEXT 33) See page 24.
9 Keypad lockout. 5 Invalid PIN codes in a row have been attempted.
You must now wait for the Keypad Lockout time to expire.
10 Zone self test fail. View the Zone Self Test History, NEXT 14.
11 Keypad Medical. Keypad Medical Alarm (7 & 9) has been activated.
12 Keypad Panic. Keypad Panic Alarm (1 & 3) has been activated.
13 Keypad Duress. A Duress PIN code has been entered on a Terminal keypad.
14 Keypad Fire. Keypad Medical Alarm (4 & 6) has been activated.
FAULT ANALYSIS LAMPS

Other manuals for Inner Range CONCEPT IQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range CONCEPT IQ and is the answer not in the manual?

Inner Range CONCEPT IQ Specifications

General IconGeneral
BrandInner Range
ModelCONCEPT IQ
CategorySecurity System
LanguageEnglish

Related product manuals