4.2) To Control an Auxiliary Output:
a) Select Auxiliary Control Mode: Press <9>, then 24 (Auxiliary Control & Test Mode)
b) Toggle the Auxiliary On or Off: Press <Auxiliary Number>, <#>
e.g. To Turn Auxiliary 3 On. Press: 3, <#>.
c) Logout of Aux Control Mode: Press <*>. (If this is not done before hanging up, you must wait
at least 30 seconds before calling the system again)
The Control Module will then reply with a Status message:
- A series of Beeps of the same tone to indicate Auxiliary On.
- A series of Beeps of 2 different tones to indicate Auxiliary Off.
- A series of Beeps of 8 different tones to indicate the operation could not be performed.
4.3) To Isolate a Zone Input:
a) Select Zone Isolate Mode: Press <9>, then 21 (Zone Isolate Mode)
b) Toggle the Zone Isolated/De-Isolated: Press <Zone Number>, <#>
e.g. To change the Status of Zone 6. Press: 6, <#>.
c) Logout of Zone Isolate Mode: Press <*>. (If this is not done before hanging up, you must wait
at least 30 seconds before calling the system again)
The Control Module will then reply with a Status message:
- A series of Beeps of the same tone to indicate Zone Isolated.
- A series of Beeps of 2 different tones to indicate Zone De-isolated.
- A series of Beeps of 8 different tones to indicate the operation could not be performed.
4.4) To Control User Auxiliary A or B:
a) At Step 3, simply Key in the User Auxiliary A PIN Code, or the User Auxiliary B PIN Code.
This will Toggle the state of the Auxiliary.
The Control Module will then reply with a Status message:
- A series of Beeps of the same tone to indicate Auxiliary On.
- A series of Beeps of 2 different tones to indicate Auxiliary Off.
- A series of Beeps of 8 different tones to indicate the operation could not be performed.
NOTE: There is a 2 minute delay required between dial-in attempts. This enhances protection against
unauthorized access into the system. Once you have hung-up the Telephone following a Telephone remote
control operation, please wait at least 2 minutes before attempting to connect again.
REMOTE CONTROL

Other manuals for Inner Range CONCEPT IQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inner Range CONCEPT IQ and is the answer not in the manual?

Inner Range CONCEPT IQ Specifications

General IconGeneral
BrandInner Range
ModelCONCEPT IQ
CategorySecurity System
LanguageEnglish

Related product manuals