29
Version 2.02 December-2002
OPERATOR FEEDBACK FOR WIRELESS REMOTE KEY OPERATIONS:
Your system may be programmed to provide audible and/or visual indication of Arm and Disarm operations
perfomed from a Wireless Remote Key. Consult with your Installer regarding your requirements.
The feedback options available are:
1) Bell Squawk: One 200milliSecond squawk in each 1 Second period.
2) Strobe Flash: One 1 Second Flash in each 2 Second period.
1) “Bell Squawk” Feedback.
A “Bell Squawk” tone on the system Siren or another sounding device can be provided and indicates the Arm
and Disarm operations in the following manner:
Arm: 1 Squawk
Disarm: 2 Squawks
Error (Already Armed): 5 Squawks
Note: No indication is provided for Home Arm and Auxiliary control operations.
2) “Strobe Flash” Feedback.
A “Strobe Flash” on the system Strobe or another indicating device can be provided and indicates the Arm
and Disarm operations in the following manner:
Arm: 1 Flash
Disarm: 2 Flashes
Error (Already Armed): 5 Flashes
Note: No indication is provided for Home Arm and Auxiliary control operations.