Chapter 10 Appendix IS580 User Manual
- 128 -
Servo Drive Model Solution 5: Require Leakage Current During Running Reducing 25% (Wind the Input or Output
Magnetic Ring One Turn).
Magnetic Ring Model
Installation Wiring Diagram Leakage Protector Selection
Reserved DY644020H
IS580
PE
R
S T
Cable
length
< 300 mm
Wind the magnetic
ring one turn.
IS580
PE
U
V W
Cable
length
< 300
mm
Wind the magnetic
ring one turn.
Action current
In
s
≥ 100
mA
IS580T035-R1-1 DY805020H
IS580T040-R1-1
IS580T050-R1-1
IS580T070-R1-1
IS580T080-R1-1 DY1207030H
IS580T080-R1-H-1
IS580T100-R1-1
IS580T100-R1-H-1
IS580T140-R1-1
IS580T140-R1-H-1
IS580T170-R1-1 DY1207030H
Action current
In
s
≥ 300
mA
IS580T170-R1-H-1
IS580T210-R1-1
IS580T210-R1-H-1