IS580 User Manual Chapter 10 Appendix
- 127 -
Servo Drive Model Solution 4: Require Leakage Current During Running Reducing 50% (Wind the Input or
Output Magnetic Ring Three Turns).
Magnetic Ring Model
Installation Wiring Diagram Leakage Protector
Selection
Reserved DY644020H For the wiring diagram of winding the output
UVW cable three turns, for the wiring diagram
in solution 5.
Note: Never run the PE cable around the
magnetic ring together with the RST cable.
IS580
PE R
S T
Cable
length
< 300 mm
Wind the magnetic
ring three turns.
Action current
In
s
≥ 100 mA
IS580T035-R1-1 DY805020H
IS580T040-R1-1
IS580T050-R1-1
IS580T070-R1-1
IS580T080-R1-1 DY1207030H
IS580T080-R1-H-1
IS580T100-R1-1
IS580T100-R1-H-1
IS580T140-R1-1
IS580T140-R1-H-1
IS580T170-R1-1 - - Action current
In
s
≥ 300 mA
IS580T170-R1-H-1
IS580T210-R1-1 - -
IS580T210-R1-H-1

Table of Contents