MD280 User Manual Description of Function Codes
- 139 -
:KHQWKHFRXQWYDOXHUHDFKHVWKHVHW FRXQWYDOXH)WKH'2WHUPLQDODOORFDWHG
ZLWKIXQFWLRQ6HWFRXQWYDOXHUHDFKHG EHFRPHV217KHQWKHFRXQWHUFRQWLQXHVWKH
counting.
:KHQWKHFRXQWLQJYDOXHUHDFKHV WKHGHVLJQDWHGFRXQWLQJYDOXH)WKH'2WHUPLQDO
DOORFDWHGZLWKIXQFWLRQ'HVLJQDWHGFRXQWYDOXHUHDFKHGEHFRPHV217KHQWKHFRXQWHU
continues to count.
Figure 6-22 Reaching the set count value and designated count value
Count pulses input
Count pulses input
Designated count
alue reached output
Set count value
reached output
123
1110 12 20 2119
12
F7-09 11
F7-08 20
Function Code Parameter Name Setting Range Default
F7-10 /RDGVSHHGGLVSOD\FRHI¿FLHQW 0.0001–6.5000 1.0000
F7-11
Number of decimal places for load
speed display
0: 0 decimal place
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
1
F7-10 is used to adjust the relationship between the output frequency of the AC drive and
the load speed.
F7-11 is used to set the number of decimal places for load speed display. The following
JLYHVDQH[DPSOHWRH[SODLQKRZWRFDOFXODWHWKHORDGVSHHG
$VVXPHWKDW)/RDGVSHHG GLVSOD\FRHIILFLHQWLVDQG)LV GHFLPDO
SODFHV:KHQWKHUXQQLQJIUHTXHQF\RIWKH$&GULYHLV+]WKHORDGVSHHGLV[
GLVSOD\RIGHFLPDOSODFHV
Function Code Parameter Name Setting Range Default
F7-12 Accumulative running time 0–65535 h -
It is used to display the accumulative running time of the AC drive. After the accumulative
running time reaches the value set in F5-12, the corresponding terminal becomes ON.
You can clear the record of this parameter by setting FP-01.