EasyManua.ls Logo

Inovance MD280NT2.2GB - Page 141

Inovance MD280NT2.2GB
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of Function Codes
MD280 User Manual
- 140 -
Function
Code
Parameter
Name
Setting Range Default
F7-13
LED display
running
parameters
1-65535
7 6 5 4 3 2 1 0
DO state
Output voltage V
DI state
Running frequency Hz
Bus voltage V
Output current A
Output power kW
Set frequency Hz
15 14 12 11 10 9 8
AI2 voltage V
PID setting
AI1 voltage V
PID feedback
13
Counted value
Pulse frequency Hz
Speed display
Length value
799
In stop state, a total of eight status parameters can be displayed, as listed in the following
table.
Function Code
Parameter
Name
Setting Range Default
F7-14
LED
display stop
parameters
1–511
7 6 5 4 3 2 1 0
Set frequency Hz
Bus voltage V
DI state
DO state
AI1 voltage V
AI2 voltage V
Counted value
Length value
15 14 13 12 11 10 9 8
Pulse frequency Hz
Reserved
51
Function Code Parameter Name Setting Range Default
F7-15
MF.K Key function
selection
0: MF.K key disabled
1: Switchover between operation panel
control and remote command control
WHUPLQDORUFRPPXQLFDWLRQ
2: Switchover between forward rotation and
reverse rotation
3: Forward JOG
0
MF.K key refers to multifunctional key. You can set the function of the MF.K key by using this
parameter. You can perform switchover by using this key both in stop or running state.
efesotomasyon.com

Table of Contents

Related product manuals