Chapter 3 Mechanical and Electrical Installation 
 
-34- 
 
Terminals  Name  Description 
terminals of DC bus 
(+) and PB 
Connecting terminal of brake 
resistor  
 
U, V and W 
Output terminal of inverter  Connect the three-phase motor 
 
Earth terminal 
Earth terminal 
3) Notes on Wiring:   
A. Input power L1, L2 or R, S and T: 
          The cable connection at the input side of the inverter has no phase sequence requirement.   
B. DC bus (+), (-) terminal: 
Note that the (+) and (-) terminals of DC bus have residual voltage right after power-on. It needs to 
make sure that the voltage is less than 42V prior to wiring connection. Otherwise there may be 
danger of electric shock.  Do not connect the brake resistor directly to the DC bus, or it may 
damage the inverter and even cause fire.   
Connecting terminals (+) and PB of brake resistor:   
      The connecting terminals of the brake resistor are effective only for the inverter of less than 
30kW with built-in brake unit.       
    The prototype of brake resistor can refer to the recommended value and the wiring length 
shall be less than 5 meters.    Otherwise it may damage the inverter.   
Terminals U, V, W at the output side of the inverter:   
    The inverter output side cannot connect to the capacitor or surge absorber.  Otherwise, it 
may cause frequent inverter protection and even damage the inverter.   
    In case the motor cable is too long, it may generate electrical resonance easily due to the 
impact of distributed capacitance, thus damaging the motor insulation or generating higher 
leakage current to invoke over current protection of the inverter. If it is over 100m, AC output 
reactor is required.   
E. Earthing terminal
˖ 
    This terminal shall be earthed reliably, with resistance of earthing cable of less than 5ȍ.  
Otherwise, it may cause fault or damage the inverter.    Do not share the earth terminal and zero 
line of the power supply.   
5. Control terminals and connection:   
  1) The control circuit terminals are arranged as follows:   
 
Fig.3-8 Layout of Control Circuit Terminals 
 