Function
code
Name LED display Set range
Minim-
um unit
Factory
default
value
Modication
description
FC-09 MS speed 9 MS speed 9
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-10 MS speed 10 MS speed 10
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-11 MS speed 11 MS speed 11
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-12 MS speed 12 MS speed 12
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-13 MS speed 13 MS speed 13
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-14 MS speed 14 MS speed 14
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-15 MS speed 15 MS speed 15
Negative maximum frequency to
maximum frequency
0.1Hz 0.0Hz
☆
FC-16
PLC running
mode
PLC mode
0:Stop upon completion
1:Keep nal value upon
completion of one-time running
2:Constant circulation
1 0
☆
FC-17
PLC power-
failur-e
recoeded
selection
PLC recoeded
0: Power failure non-recorded
1: Power failure recorded
0 0
☆
FC-18
Running
time of zero-
segment of
PLC
Zero-segment
time
0.0s(h)
~
6553.5s(h)
0.1s
(
h
)
0.0s
(
h
) ☆
FC-19
Speed-up/
speed-down
time selection
of zero-
segment of
PLC
Speed-up/
speed-down of
zero-segment
0
~
3 1 0
☆
FC-20
First segment
running time
of PLC
First -segment
time
0.0s(h)
~
6553.5s(h)
0.1s
(
h
)
0.0s
(
h
) ☆
FC-21
First -segment
speed-up/
speed-down
time selection
of PLC
First -segment
speed-up/
speed-down
0
~
3 1 0
☆
FC-22
Second
-segment
running time
of PLC
Second
-segment time
0.0s(h)
~
6553.5s(h)
0.1s
(
h
)
0.0s
(
h
) ☆