EasyManua.ls Logo

Inovance MD380-5T5.5GB - Page 103

Inovance MD380-5T5.5GB
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Code Table
MD380 User Manual
- 102 -
)unction
Code
Parameter Name
Setting Range
Default Property
)9-13
Output phase loss protection
selection
0: Disabled
1: Enabled
1 ƿ
)9-14 1st fault type
0: No fault
1: Reserved
2: Overcurrent during acceleration
3: Overcurrent during deceleration
4: Overcurrent at constant speed
5: Overvoltage during
acceleration
6: Overvoltage during
deceleration
7: Overvoltage at constant speed
%XIIHUUHVLVWDQFHRYHUORDG
9: Undervoltage
10: AC drive overload
11: Motor overload
12:Power input phase loss
13: Power output phase loss
14: Module overheat
15: External equipment fault
16: Communication fault
17: Contactor fault
18: Current detection fault
19: Motor auto-tuning fault
20: Encoder/PG card fault
21: EEPROM read-write fault
22: AC drive hardware fault
23: Short circuit to ground
24: Reserved
25: Reserved
26: Accumulative running time
reached
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
29: Accumulative power-on time
reached
30: Load becoming 0
31: PID feedback lost during
running
- ƽ
)9-15 2nd fault type - ƽ
efesotomasyon.com

Table of Contents

Related product manuals