Function Code Table
MD380 User Manual
- 104 -
)unction
Code
Parameter Name
Setting Range
Default Property
)9-47
)ault protection
action selection 1
Unit's digit (Motor overload, Err11)
00000 ƿ
0: Coast to stop
1: Stop according to the stop
mode
2: Continue to run
Ten's digit (Power input phase
loss, Err12)
Same as unit's digit
Hundred's digit (Power output
phase loss, Err13)
Same as unit's digit
Thousand's digit (External
equipment fault, Err15)
Same as unit's digit
Ten thousand's digit
(Communication fault, Err16)
Same as unit's digit
)9-48
)ault protection
action selection 2
Unit's digit (Encoder fault, Err20)
00000 ƿ
0: Coast to stop
6ZLWFKRYHUWR9)FRQWUROVWRS
according to the stop mode
6ZLWFKRYHUWR9)FRQWURO
continue to run
Ten's digit (EEPROM read-write
fault, Err21)
0: Coast to stop
1: Stop according to the stop
mode
)9-48
)ault protection action
selection 2
Hundred's digit: reserved
00000 ƿ
Thousand's digit (Motor overheat,
Err25)
6DPHDVXQLWVGLJLWLQ)
Ten thousand's digit
(Accumulative running time
reached)
6DPHDVXQLWVGLJLWLQ)