Function Code Table
MD380 User Manual
- 108 -
)unction
Code
Parameter Name
Setting Range
Default Property
)A
-24
Maximum deviation between
two PID outputs in reverse
direction
0.00%–100.00%
1.00% ƿ
)A
-25 PID integral property
Unit's digit (Integral separated)
00 ƿ
0: Invalid
1: Valid
Ten's digit (Whether to stop
integral operation when the output
reaches the limit)
0: Continue integral operation
1: Stop integral operation
)A
-26
Detection value of
PID feedback loss
0.0%: Not judging feedback loss
0.1%–100.0%
0.0% ƿ
)A
-27
Detection time of
PID feedback loss
0.0–20.0s
0.0s ƿ
)A
-28 PID operation at stop
0: No PID operation at stop
1: PID operation at stop
0 ƿ
Group )%: Swing )requency,
)ixed Length and Count
)%-00
Swing frequency setting
mode
0: Relative to the central
frequency
1: Relative to the maximum
frequency
0 ƿ
)%-01 Swing frequency amplitude
0.0%–100.0%
0.0% ƿ
)%-02 Jump frequency amplitude
0.0%–50.0%
0.0% ƿ
)%-03 Swing frequency cycle
0.0–3000.0s
10.0s ƿ
)%-04
Tr
iangular wave rising time
coef¿cient
0.0%–100.0%
50.0% ƿ
)%-05 Set length
0–65535 m
1000 m ƿ
)%-06 Actual length
0–65535 m
0 m ƿ
)%-07 Number of pulses per meter
0.1–6553.5
100.0 ƿ
)%-08 Set count value
1–65535
1000 ƿ
)%-09 Designated count value
1–65535
1000 ƿ
Group )C: Multi-Reference and Simple PLC )unction
)C-00 Reference 0
-100.0%–100.0%
0.0% ƿ
)C-01 Reference 1
-100.0%–100.0%
0.0% ƿ
)C-02 Reference 2
-100.0%–100.0%
0.0% ƿ
)C-03 Reference 3
-100.0%–100.0%
0.0% ƿ
)C-04 Reference 4
-100.0%–100.0%
0.0% ƿ