MD380 User Manual Function Code Table
- 131 -
)unction
Code
Parameter Name
Setting Range
Default Property
A7-08
Command given by the user
programmable card
)RUZDUG581
2: Reverse RUN
)RUZDUG-2*
4: Reverse JOG
5: Coast to stop
6: Decelerate to stop
)DXOWUHVHW
0 ƿ
A7-09
)aults given by the user
programmable card
0: No fault
±)DXOWFRGHV
0 ƿ
Group A
8: Point-point Communication
A8-00
Point-point communication
selection
0: Disabled
1: Enabled
0 ƿ
A8-01 Master and slave selection
0: Master
1: Slave
0 ƿ
A8-02
Slave following master
command selection
0: Slave not following running
commands of the master
1: Slave following running
commands of the master
0 ƿ
A8-03
Usage of data received by
slave
7RUTXHVHWWLQJ)UHTXHQF\
setting
0 ƿ
A8-04
=ero off
set of received data
(torque)
-100.00%–100.00%
0.00% ƾ
A8-05
Gain of received data
(torque)
-10.00–10.00
1.00 ƾ
A8-06
Point-point communication
interruption detection time
0.0–10.0s
1.0s ƿ
A8-07 Master data sending cycle
0.001–10.000s
0.001s ƿ
A8-08
=ero off
set of received data
zero offset (frequency)
-100.00%–100.00%
0.00% ƾ
A8-09
Gain of received data gain
(frequency)
-10.00–10.00
1.00 ƾ
A8-10
Runaway prevention
coef¿cient
0.00%–100.00%
10.00% ƾ
Group A
C: AI/AO Correction
AC-00 AI1 measured voltage 1
0.500–4.000 V
)actory
corrected
ƿ
AC-01 AI1 displayed voltage 1
0.500–4.000 V
)actory
corrected
ƿ
AC-02 AI1 measured voltage 2
6.000–9.999 V
)actory
corrected
ƿ