Description of Function Codes
MD380 User Manual
- 202 -
)unction Code Parameter Name Description
)9-20 DI status upon 3rd fault
It displays the status of all DI terminals when
the latest fault occurs.
The sequence is as follows:
If a DI is ON, the setting is 1. If the DI is O)),
the setting is 0. The value is the equivalent
decimal number converted from the DI status..
)9-21
Output terminal status
upon 3rd fault
It displays the status of all output terminals
when the latest fault occurs.
The sequence is as follows:
If an output terminal is ON, the setting is 1.
If the output terminal is O)), the setting is 0.
The value is the equivalent decimal number
converted from the DI statuses.
)9-22
AC drive status upon 3rd
fault
Reserved
)9-23
Power-on time upon 3rd
fault
It displays the present power-on time when the
latest fault occurs.
)9-24
Running time upon 3rd
fault
It displays the present running time when the
latest fault occurs.
)9-27 )requency upon 2nd fault
Same as )9-17–)9-24.
)9-28 Current upon 2nd fault
)9-29 %us voltage upon 2nd fault
)9-30 DI status upon 2nd fault
)9-31
Output terminal status
upon 2nd fault
)9-32 )requency upon 2nd fault
)9-33 Current upon 2nd fault
)9-34 %us voltage upon 2nd fault
)9-37 DI status upon 1st fault
Same as )9-17–)9-24.
)9-38
Output terminal status
upon 1st fault
)9-39 )requency upon 1st fault
)9-40 Current upon 1st fault
)9-41 %us voltage upon 3rd fault
)9-42 DI status upon 1st fault
)9-43
Output terminal status
upon 1st fault
)9-44 )requency upon 1st fault