MD380 User Manual Function Code Table
- 81 -
)unction
Code
Parameter Name
Setting Range
Default Property
)0-03
Main frequency source X
selection
5: Pulse setting (DI5)
6: Multi-reference
7: Simple PLC
8: PID
9: Communication setting
0 ƾ
)0-04
Auxiliary frequency source Y
selection
7KHVDPHDV)0DLQ
frequency source X selection)
0 ƾ
)0-05
Range of auxiliary frequency
Y
for X and Y operation
0: Relative to maximum frequency
1: Relative to main frequency X
0 ƿ
)0-06
Range of auxiliary frequency
Y
for X and Y operation
0%–150%
100% ƿ
)0-07 )requency source selection
8QLWVGLJLW)UHTXHQF\VRXUFH
selection)
00 ƿ
0: Main frequency source X
1: X and Y operation
(operation relationship determined
by ten's digit)
2: Switchover between X and Y
3: Switchover between X and "X
and Y operation"
4: Switchover between Y and "X
and Y operation"
Ten's digit (X and Y operation
relationship)
0: X+Y
1: X-Y
2: Maximum
3: Minimum
)0-08 Preset frequency
0.00 to maximum frequency (valid
when frequency source is digital
setting)
50.00 Hz ƿ
)0-09 Rotation direction
0: Same direction
1: Reverse direction
0 ƿ
)0-10 Maximum frequency
50.00–320.00 Hz
50.00 Hz ƾ
)0-11
Source of frequency upper
limit
6HWE\)
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Communication setting
0 ƾ
efesotomasyon.com