MD380 User Manual Function Code Table
- 87 -
)unction
Code
Parameter Name
Setting Range
Default Property
)3-05
Multi-point V/) frequency 2
()2)
)WR)
0.00 Hz ƾ
)3-06
Multi-point V/) voltage 2
(V2)
0.0%–100.0%
0.0% ƾ
)3-07
Multi-point V/) frequency 3
()3)
)WRUDWHGPRWRUIUHTXHQF\
)
Note: The rated frequencies
of motors 2, 3, and 4 are
respectively set in A2-04, A3-04,
and A4-04.
0.00 Hz ƾ
)3-08
Multi-point V/) voltage 3
(V3)
0.0%–100.0%
0.0% ƾ
)3-09 V/) slip compensation gain
0%–200.0%
0.0% ƿ
)3-10 V/) over-excitation gain
0–200
64 ƿ
)3-11
V/) oscillation suppression
gain
0–100
Model
dependent
ƿ
)3-13
Vo
ltage source for V/)
separation
'LJLWDOVHWWLQJ)
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Multi-reference
6: Simple PLC
7: PID
8: Communication setting
100.0% corresponds to the rated
PRWRUYROWDJH)$$
02, A6-02).
0 ƿ
)3-14
Vo
ltage digital setting for V/
) separation
0 V to rated motor voltage
0 V ƿ
)3-15
Vo
ltage rise time of V/)
separation
0.0–1000.0s
It indicates the time for the
voltage rising from 0 V to rated
motor voltage.
0.0s ƿ
)3-16
Voltage decline time of V/)
separation
0.0–1000.0s
It indicates the time for the
voltage to decline from rated
motor voltage to 0 V.
0.0s ƿ
)3-17
Stop mode selection upon
V/) separation
)UHTXHQF\
and voltage
declining to 0 independently
1: )requency decli
ning after
voltage declines to 0
0 ƿ