Function Code Table
MD380 User Manual
- 96 -
)unction
Code
Parameter Name
Setting Range
Default Property
)6-08
Ti
me proportion of S-curve
start segment
WR±)
30.0% ƾ
)6-09
Ti
me proportion of S-curve
end segment
WR±)
30.0% ƾ
)6-10 Stop mode
0: Decelerate to stop
1: Coast to stop
0 ƿ
)6-11
Initial frequency of stop DC
braking
0.00 Hz to maximum frequency
0.00 Hz ƿ
)6-12
Wa
iting time of stop DC
braking
0.0–36.0s
0.0s ƿ
)6-13 Stop DC braking current
0%–100%
0% ƿ
)6-14 Stop DC braking time
0.0–36.0s
0.0s ƿ
)6-15 %rake use ratio
0%–100%
100% ƿ
Group )7: Operation Panel and Display
)7-01 M).
K Key function selection
0).NH\GLVDEOHG
1: Switchover between operation
panel control and remote
command control (terminal or
communication)
2: Switchover between forward
rotation and reverse rotation
)RUZDUG-2*
4: Reverse JOG
0 ƾ
)7-02 STO
P/RESET key function
0: STOP/RESET key enabled
only in operation panel control
1: STOP/RESET key enabled in
any operation mode
1 ƿ
)7-03
LED display running
parameters 1
±))))
%LW5XQQLQJIUHTXHQF\+]
%LW6HWIUHTXHQF\+]
%LW%XVYROWDJH9
%LW2XWSXWYROWDJH9
%LW2XWSXWFXUUHQW$
%LW2XWSXWSRZHUN:
%LW2XWSXWWRUTXH
%LW',LQSXWVWDWXV
1) ƿ