A
Amy HernandezAug 25, 2025
Why does Inovance MD380-5T5.5GB DC Drives have overcurrent during acceleration?
- DDr. Emily BennettAug 25, 2025
When an Inovance DC drive experiences overcurrent during acceleration, it may be due to a grounded or short-circuited output circuit, failure to perform motor auto-tuning, an excessively short acceleration time, an inappropriate manual torque boost or V/F curve, low voltage, starting a rotating motor, a sudden load during acceleration, or an undersized AC drive. To address this, eliminate external faults, perform motor auto-tuning, increase the acceleration time, adjust the manual torque boost or V/F curve, correct the voltage, use rotational speed tracking restart or wait for the motor to stop before starting, remove the added load, or select an AC drive with a higher power class.