EasyManua.ls Logo

Inovance MD600 Series - AC Drive Wiring; Pre-Wiring Inspection; Main Circuit Wiring

Inovance MD600 Series
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC Drive Wiring
‑19‑
5 AC Drive Wiring
5.1 Pre-wiring Inspection
Complete the following inspection items before wiring.
Table 5–1 Pre‑wiring inspection checklist
No. Item
Checked
1
The diameter and shield of the cables used meet corresponding
requirements.
2
The device and the drive are grounded properly.
3
Proper electrostatic discharge (ESD) procedures are followed and
antistatic wrist straps are worn.
5.2 Main Circuit Wiring
CCoonntteexxtt
For details on main circuit terminals, see "Electrical Design" in the
MD600 Series Basic
AC Drive Hardware Guide
. This section describes quick main circuit wiring. The follow‑
ing procedure takes the CAN model as an example to introduce how to wire the main
circuit.
PPrroocceedduurree
1. Ground the AC drive.
2. Check the rated value of the circuit breaker or fuse.
3. Check whether the rated motor voltage is compatible with the AC drive voltage.
4. Connect the AC drive to the motor.
5. Connect the AC drive to the mains power.