Quick Operation
‑31‑
Pa
rame
ter
Code
Param
eter
Name
De
fault
Value Range
Description
A0‑00
Param
eter
initiali
zation
0
0: No operation
1: Restore parameters
excluding motor
parameters to default
settings
2: Clear records
3: Restore parameters
including motor
parameters to default
settings
4: Back up current
user parameters
5: Clear fault
information
501: Restore user
backed‑up
parameters
503: Restore
parameters including
motor parameters to
default settings and
clear records
0: No operation
1: AC drive parameters except factory
parameters, motor parameters, and
records are restored to default settings.
2: Fault records, cumulative running
time, cumulative power‑on time, and
cumulative power consumption are
cleared.
3: AC drive parameters except factory
parameters and records are restored to
default settings.
4: The current parameter settings are
backed up, which is the same as the
function when A0‑09 is set to 400.
5: Fault information is cleared.
501: Parameters backed up by setting
A0‑00 to 4 are stored, which is the same
as the function when A0‑08 is set to 500.
503: AC drive parameters except factory
parameters are restored to default
settings and records are cleared. Factory
parameters include the model
parameters, AI/AO correction
parameters. Record information
parameters include the fault record,
cumulative running time, and cumulative
power‑on time.
6.3.4 Checking Software Versions
The product software version includes the performance software version and function
software version. You can check the software version to ensure that it is consistent
with the actual product version.
Param
eter
Code
Parameter Name
Value Range
Description
A2‑22
Performance
software version
0.00‑655.35
This parameter displays the
performance software version of the
AC drive.
A2‑23
Function software
version
0.00‑655.35
This parameter displays the function
software version of the AC drive.