Quick Operation
‑24‑
Table 6–2 Status description
Symbol
Name
Function Status
FWD
Forward running Steady on: The AC drive is
running forwardly or the forward
running mode is set.
REV
Reverse running
Steady on: The AC drive is
running reversely or the reverse
running mode is set.
Local/remote Local/remote
connection mode
● Off: local control
● Steady on: Terminal control
● Flashing: Communication
control
● Flashing quickly: User‑defined
control mode
Torque control Torque control
mode
Steady on: Torque control mode
Off: Speed control mode
Alarm Alarm state Steady on: A fault or an alarm
occurs.
Running Running status
Steady on: The AC drive is
running.
Off: The AC drive does not run.
Table 6–3 Key descriptions
Key Name
Function
Menu/Back key In the monitoring interface, press the key to enter
the parameter setting interface.
In the parameter interface, press the key to return
to the last interface or undo the operation.
Long press the key to enter the multi‑function
menu.
OK key Press the key to enter the settings interface or
confirm settings.
Up key In the monitoring interface, press the key to
increase the value of the potentiometer.
In the parameter interface, press the key to increase
the parameter number.