Quick Operation
48
Param
eter
Code
Parameter
Name
Default Value Range
Description
d0‐29 DC braking
time for stop
0.0s 0.0s to 100.0s
During deceleration to stop,
when the operating frequency is
reduced to d0‑27, the drive
blocks the output for the time
set by d0‑28, outputs the DC
braking current set by d0‑30 for
the time set by d0‑29, and then
enters the shutdown state.
d0‐30 DC braking
current for
stop
50% 0% to 100.0%
During deceleration to stop,
when the operating frequency is
reduced to d0‑27, the drive
blocks the output for the time
set by d0‑28, outputs the DC
braking current set by d0‑30 for
the time set by d0‑29, and then
enters the shutdown state. The
actual DC braking current is d0‑
30 x rated motor current. A
larger value indicates stronger
braking force.