EasyManua.ls Logo

Inovance Monarch NICE-L-C-4037F

Inovance Monarch NICE-L-C-4037F
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 System Commissioning
-
167
-
5.6 Riding Comfort Adjustment
Riding comfort
adjustment during running
Leveling accuracy
adjustment
Riding comfort adjustment at
elevator startup and stop
Riding comfort adjustment to the
running curve
Riding comfort
adjustment
Description of leveling
components
All-floor leveling accuracy
adjustment
Single-floor leveling
accuracy adjustment
5.6.1 Riding Comfort Adjustment
The riding comfort is an important factor of the elevator󶙔s overall performance. Im-
proper installation of mechanical parts and improper parameter settings will cause
discomfort. Enhancing the riding comfort mainly involves adjustment of the controller
output and the elevator󶙔s mechanical construction.
1 Performance adjustment of system control
V (speed)
t
(time)
RUN contactor
Brake contactor
Shorting door lock
circuit contactor
Shorting PMSM stator
contactor
Internal running status
Leveling signal
RUN contactor feedback
Brake contactor feedback
Shorting door lock circuit
contactor feedback
Shorting PMSM stator
contactor feedback
F2
-16
F3
-18
F3-19
F
3-
20
F8
-11
F
2-17
󶙽Running time sequence

Table of Contents